Citrix Provisioning Console Configuration – Carl Stalhood (2024)

Last Modified: Apr 19, 2024 @ 4:19 am

Navigation

This article applies to all 7.x versions of Citrix Provisioning, including 2402, LTSR 2203 CU4, LTSR 1912 CU7, and LTSR 7.15.45 (aka LTSR 7.15 CU9).

  • Change Log
  • Launch the Console
  • Farm Properties
  • Server Properties
  • vDisk Stores
  • Device Collections
  • Prevent “No vDisk Found” PXE Message

Change Log

Launch the Provisioning Console

  1. Launch the Citrix Provisioning Console.
    Citrix Provisioning Console Configuration – Carl Stalhood (1)
  2. Right-click the top-left node and click Connect to Farm.
    Citrix Provisioning Console Configuration – Carl Stalhood (2)
  3. Enter localhost andclick Connect.
    Citrix Provisioning Console Configuration – Carl Stalhood (3)
  4. In large multi-domain environments, or when older domains are still configured but are unreachable, if you seeServer communication timeout, then seeCTX231194PVS Console Errors: “Critical Error: Server communication timeout” for a registry key to skip forest level trusts, a registry key to increase the console timeout, and a .json file to blacklist domains.
    Citrix Provisioning Console Configuration – Carl Stalhood (4)

Farm Properties

  1. Right-click the farm name and click Properties.
    Citrix Provisioning Console Configuration – Carl Stalhood (5)
  2. On the Groups tab, add the Citrix Admins group.
    Citrix Provisioning Console Configuration – Carl Stalhood (6)
  3. On the Security tab, add the Citrix Administrators group to grant it full permission to the entire Provisioning farm. You can also assign permissions in various nodes in the Provisioning console. Citrix Provisioning 2311 and newer let you restrict a group to Read-only access.
    Citrix Provisioning Console Configuration – Carl Stalhood (7)
  4. On the Options tab, check the boxes next to Enable Auditing, and Enable offline database support.
    Citrix Provisioning Console Configuration – Carl Stalhood (8)
    • With Auditing enabled, you can right-click on objects and click Audit Trail to view the configuration changes.
      Citrix Provisioning Console Configuration – Carl Stalhood (9)
      Citrix Provisioning Console Configuration – Carl Stalhood (10)
  5. In some versions of Citrix Provisioning, you might see a Send anonymous statistics and usage information checkbox, which enables Customer Experience Improvement Program (CEIP).Seehttps://www.carlstalhood.com/delivery-controller-cr-and-licensing/#ceip for additional places where CEIP is enabled.
    Citrix Provisioning Console Configuration – Carl Stalhood (11)
  6. If you see a Problem Report tab, you can enter MyCitrix credentials. This tab was removed in Provisioning 2209.
    Citrix Provisioning Console Configuration – Carl Stalhood (12)
  7. Click OK to close Farm Properties.
  8. Click OK when prompted that a restart of the service is required.
    Citrix Provisioning Console Configuration – Carl Stalhood (13)

Server Properties

  1. Expand the Provisioning Site and click Servers.
  2. For each Provisioning Server, right-click it, and click Configure Bootstrap.
    Citrix Provisioning Console Configuration – Carl Stalhood (14)
  3. Click Read Servers from Database. This should cause both servers to appear in the list.
    Citrix Provisioning Console Configuration – Carl Stalhood (15)
  4. From Carl Fallis at PVS HA at Citrix Discussions:when stopping the stream service through the console the Provisioning server will send a message to the targets to reconnect to another server before the stream service shuts down. The target then uses the list of login servers (Bootstrap servers) and reconnects to another server, this is almost instantaneous failover and can’t really be detect . In the case of the Provisioning server failing the target detects it and reconnects, slightly different mechanism and the target may hang for a short time. Check out the following article for more informationhttps://www.citrix.com/blogs/2014/10/16/provisioning-services-failover-myth-bustedfor the Provisioning server failure case.
  5. On the Options tab, check the box next to Verbose mode.
    Citrix Provisioning Console Configuration – Carl Stalhood (16)
  6. Right-click the server, and click Properties.
    Citrix Provisioning Console Configuration – Carl Stalhood (17)
  7. On the General tab, check the box next to Log events to the server’s Windows Event Log.
    Citrix Provisioning Console Configuration – Carl Stalhood (18)
  8. Click Advanced.
    Citrix Provisioning Console Configuration – Carl Stalhood (19)
  9. Citrix Blog Post From Legacy to Leading Edge: The New Citrix Provisioning Guidelines says Avoid Modifying the Threads Per Port and Streaming Ports. The old guidance was for the number of threads per port should match the number of vCPUs assigned to the server.
    Citrix Provisioning Console Configuration – Carl Stalhood (20)
  10. On the same tab are concurrent I/O limits. Note that these throttle connections to local (drive letter) or remote (UNC path) storage. Setting them to 0 turns off the throttling. Only testing will determine the optimal number.
    Citrix Provisioning Console Configuration – Carl Stalhood (21)
  11. Click OK to closeAdvanced Server Properties.
  12. On the Network tab,Citrix Blog Post From Legacy to Leading Edge: The New Citrix Provisioning Guidelines says Avoid Modifying the Threads Per Port and Streaming Ports. The old guidance was to change the Last port to 6968.
    • Note: port 6969 is used by the Provisioning two-stage boot (Boot ISO) component.
    • You can set the First port to 7000 to avoid port 6969 and get more ports.
    • Citrix Provisioning 1811 and newer open Windows Firewall ports during installation, but Citrix Provisioning Console will not change the Windows Firewall rules based on what you configure here. You’ll need to adjust the Windows Firewall rules manually.
  13. Click OK when done.
    Citrix Provisioning Console Configuration – Carl Stalhood (22)
  14. Click Yes if prompted to restart the stream service.
    Citrix Provisioning Console Configuration – Carl Stalhood (23)
  15. If you get an error message about the stream service then you’ll need to restart it manually.
    Citrix Provisioning Console Configuration – Carl Stalhood (24)
    Citrix Provisioning Console Configuration – Carl Stalhood (25)
  16. From Carl Fallis at PVS HA at Citrix Discussions:when stopping the stream service through the console the Provisioning server will send a message to the targets to reconnect to another server before the stream service shuts down. The target then uses the list of login servers and reconnects to another server, this is almost instantaneous failover and can’t really be detect . In the case of the Provisioning server failing the target detects it and reconnects, slightly different mechanism and the target may hang for a short time. Check out the following article for more informationhttps://www.citrix.com/blogs/2014/10/16/provisioning-services-failover-myth-bustedfor the Provisioning server failure case.
  17. Repeat for the other servers. You can copy the Server Properties from the first server, and paste them to additional servers.
    Citrix Provisioning Console Configuration – Carl Stalhood (26)
    Citrix Provisioning Console Configuration – Carl Stalhood (27)
    Citrix Provisioning Console Configuration – Carl Stalhood (28)
    Citrix Provisioning Console Configuration – Carl Stalhood (29)

Create vDisk Stores

To create additional vDisk stores (one per vDisk / Delivery Group / Image), do the following:

  1. On the Provisioning servers, using Explorer, go to the local disk containing the vDisk folders and create a new folder. The folder name usually matches the vDisk name. Do this on both Provisioning servers.
  2. In the Provisioning Console, right-click Stores, and click Create Store.
    Citrix Provisioning Console Configuration – Carl Stalhood (30)
  3. Enter the name for the vDisk store, and select an existing site.
    Citrix Provisioning Console Configuration – Carl Stalhood (31)
  4. Switch to the Servers tab. Check the boxes next to the Provisioning Servers.
    Citrix Provisioning Console Configuration – Carl Stalhood (32)
  5. On the Paths tab, enter the path for the Delivery Group’svDisk files. Shared SMB paths are supported as described at Citrix Blog Post PVS Internals #4: vDisk Stores and SMB3.
  6. Click Validate.
    Citrix Provisioning Console Configuration – Carl Stalhood (33)
  7. Click Close and then click OK.
    Citrix Provisioning Console Configuration – Carl Stalhood (34)
  8. Click Yes when asked for the location of write caches.
    Citrix Provisioning Console Configuration – Carl Stalhood (35)

Create Device Collections

  1. Expand the site, right-click Device Collections, and click Create Device Collection.
    Citrix Provisioning Console Configuration – Carl Stalhood (36)
  2. Name the collection in some fashion related to the name of the Delivery Group, and click OK.
    Citrix Provisioning Console Configuration – Carl Stalhood (37)

If you are migrating from one Provisioning farm to another, see Kyle WiseHow To Migrate PVS Target Devices.

Prevent “No vDisk Found” PXE Message

If PXE is enabled on your Provisioning servers, and if you PXE boot a machine that is not added as a device in the Provisioning console, then the machine will pause booting with a “No vDisk Found” message at the BIOS boot screen. Do the following to prevent this.

  1. Enable the Auto-Add feature in the farm Properties on theOptions tab.
    Citrix Provisioning Console Configuration – Carl Stalhood (38)
    Citrix Provisioning Console Configuration – Carl Stalhood (39)
  2. Createa small dummy vDisk (e.g. 100 MB).
    Citrix Provisioning Console Configuration – Carl Stalhood (40)
    Citrix Provisioning Console Configuration – Carl Stalhood (41)
  3. Create a dummy Device Collection.
    Citrix Provisioning Console Configuration – Carl Stalhood (42)
    Citrix Provisioning Console Configuration – Carl Stalhood (43)
  4. Create a dummy device.
    Citrix Provisioning Console Configuration – Carl Stalhood (44)
  5. Set it to boot from Hard Disk
    Citrix Provisioning Console Configuration – Carl Stalhood (45)
  6. Assign the dummy vDisk and click OK.
    Citrix Provisioning Console Configuration – Carl Stalhood (46)
  7. Set the dummy device as the Template.
    Citrix Provisioning Console Configuration – Carl Stalhood (47)
    Citrix Provisioning Console Configuration – Carl Stalhood (48)
  8. Right-click the site, and click Properties.
    Citrix Provisioning Console Configuration – Carl Stalhood (49)
  9. On the Options tab,point the Auto-Add feature to Dummy collection, and click OK.
    Citrix Provisioning Console Configuration – Carl Stalhood (50)

Related Topics

  • Prepare a Master Target Device
  • Back to Citrix Provisioning
Citrix Provisioning Console Configuration – Carl Stalhood (2024)
Top Articles
Latest Posts
Article information

Author: Foster Heidenreich CPA

Last Updated:

Views: 6248

Rating: 4.6 / 5 (76 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Foster Heidenreich CPA

Birthday: 1995-01-14

Address: 55021 Usha Garden, North Larisa, DE 19209

Phone: +6812240846623

Job: Corporate Healthcare Strategist

Hobby: Singing, Listening to music, Rafting, LARPing, Gardening, Quilting, Rappelling

Introduction: My name is Foster Heidenreich CPA, I am a delightful, quaint, glorious, quaint, faithful, enchanting, fine person who loves writing and wants to share my knowledge and understanding with you.